• Shopping Cart
  • Your shopping cart is empty!

  • Favorite
  • Your wish list is empty.

Forgotten Password

or

80K RF Professional Cavitation Machine, 9in1 Body Slimming Device, with EMS Microcurrent Pad, for SPA Salon

Special
  • days
  • :
  • :
  • :
$659.99 $1,399.99 52% OFF Tax Free & VAT Included
Free express shipping at $30.00
  • Buy FREYARA 80k rf professional cavitation machine, 9in1 body slimming device, with ems microcurrent pad, for spa salon online, worldwide free shipping and 30 days return guarantee.
  • TS00103MS
  • SKU: TS00103MS
  • 659.99
In Stock
30
Description:
  • * Thank you for your support of Freyara. Exclusive flash sale is your exclusive benefit, a certain amount will be released every day during the event, so good luck grabbing it!
  • * If you missed it and need to buy this product. Click to be redirected to the same product!
  • * Exclusive flash sale products, No discounts! Refunds for price difference between the same product and this product are not supported!

DownLoad Instruction :

Payment:
1
1
1
1
1
1
1
1
1
1
1
1

this pro machine has 9 functions, can provide the most popular SPA care services for the eyes, face, neck, arms, back, abdomen, thighs and other parts. We recommend downloading the manual from this page in order to learn more about their functions and principles.

you can create personalized beauty massage services based on the 9 functions of the machine, where 95% of the needs can be met, and premium service experience is the key to improving the service quality of SPA or studios and increasing customer satisfaction.

The 2.0 version handle has more concentrated energy than other flat probes and produces less noise, improving the experience of customers and beauticians. This page provides a handle test video that can be used to determine if the 2.0 handle is working properly.

Meeting the needs of each customer: There are 9 energy levels and different working modes, and the machine can be set to work for 0-60 minutes. you can provide the most suitable beauty and body massage services to your customers.

 

Functions of Different Head:

3 RF head: suit for 1-2 energy
When using, select the 3-pole RF head and enter the function panel.
MODE: (A: red light is always on), (B: red light flashes every 1 second), (C: red light flashes every 2 seconds), (D: red light flashes every 3 seconds).
TIME: The default is 30 minutes, adjustable from Oto 60 minutes. When it is 0, the instrument will stop working.
ENERGY: Adjust the RF energy of the working head. The larger the number, the greater the energy. The 10th gear can be adjusted.
Use for face or eye:
When use on the skin, it can firms and lifts theskin, reduces winkle.Improvement eyes circulation, shrink pores, and puffy eyes.Eliminate wrinkles, dark circles and bags under the eyes.Improve skin texture and eliminate sagging eyes. Rejuvenates the skin and improves eye contour.

4 RF head: suit for 2-3 energy
When using, select the 4-pole RF head and enter the function panel.
MODE: (A: red light is always on), (B: red light flashes every 1 second), (C: red light flashes every 2 seconds), (D: red light flashes every 3 seconds).
TIME: The default is 30 minutes, adjustable from Oto 60 minutes. When it is 0, the instrument will stop working.
ENERGY: Adjust the RF energy of the working head. The larger the number, the greater the energy. The 10th gear can be adjusted.
Use for the face and neck
Firm skin, enhance skin elasticity, facial wrinkle elimination, skin tightening and lifting,reduce face swelling, reduce redness, relieve eye fatigue, remove dark circles, And eye bags, improve skin quality.

6 RF head: suit for 2-5 energy
When using, select the 6-pole RF head and enter the function panel.
MODE: (A: red light is always on), (B: red light flashes every 1 second), (C: red light flashes every 2 seconds), (D: red light flashes every 3 seconds).
TIME: The default is 30 minutes, adjustable from Oto 60 minutes. When it is 0, the instrument will stop working.
ENERGY: Adjust the RF energy of the working head. The larger the number, the greater the energy. The 10th gear can be adjusted.
Use for the back and waist of Body, thighs and calves
Can tighten the waist, firm and help body shaping. Soften the muscles of the arms and thighs, give the whole body massage and tighten the arms and thighs.

80k fat burn head
When using, select the SOK Fat Burn Head and enter the function panel.
MODE: (A: continuous vibration), (B: stop for 1 second per vibration), (C: stop for 2 seconds per vibration), (D: stop for 3 seconds per vibration).
TIME: The default is 30 minutes, adjustable from Oto 60 minutes. When it is 0, the instrument will stop working.
ENERGY: Adjust the vibration energy of the working head. The larger the number, the greater the energy. The 10th gear can be adjusted.
Use for the body Shaping
It can dissolve fat, detoxify lymph, tighten skin, enhance skin elasticity, reach fat layer directly, have the function of directional RF output, accelerate the movement of fat cells to generate heat energy, and discharge the excess fat and toxin in the face out of the body through sweat glands, liver intestine circulation and lymph circulation, so as to dissolve fat.

negative pressure massage head
When using, select the Negative pressure massage Head and enter the function panel.
MODE: (A: red light is always on), (B: red light flashes every 1 second), (C: red light flashes every 2 seconds), (D: red light flashes every 3 seconds).
TIME: The default is 30 minutes, adjustable from Oto 60 minutes. When it is 0, the instrument will stop working.
ENERGY: Adjust the RF energy of the working head. The larger the number, the greater the energy. The 10th gear can be adjusted.
SUCTION: Adjust the suction time of negative pressure. The larger the number is, the longer the suction time will be. It is invalid when it is 0.
RELEASE: Adjust the suction time of negative pressure. The larger the number is, the longer the suction time is. It is invalid when it is 0.
Note: The inspiratory and outgassing intervals are only available when the number is adjusted at the same time.
Body maintenance
Diversified level adjustment make your body to be care comfortably.Improve skin texture by promoting the regeneration of collagen and elasticity.Improve skin sagging caused by fat and skin aging.Help eliminate waste materials in the body and promote metabolism.Negative pressure massage function can promote fat cell volume reduction.Vacuum negative pressure massage can fully absorb various skin tissues between the multi-polar thermal melting radio frequency, so that the radio frequency energy can reach the deep skin tissue more effectively.At the same time, the adsorption of negative pressure promotes blood circulation and metabolism. Let the muscle tissue be fully relaxed and relieve the fatigue of the skin and muscle tissue.

Laser Lipolysis
When using, select the Laser Lipolysis and enter the function panel.
MODE: (A: red light is always on), (8: red light flashes every 1 second), (C: red light flashes every 2 seconds), (D: red light flashes every 3 seconds).
TIME: The default is 30 minutes, adjustable from Oto 60 minutes. When it is 0, the instrument will stop working.
ENERGY: Adjust the micro-electric energy of the working head. The larger the number, the greater the energy. The 10th gear can be adjusted.
LIGHT:Adjust the brightness of the laser panel lamp. The greater the number, the greater the brightness. The 10th gear can be adjusted.
Use for the body Shaping
The Following information is provided for the correct utilization of IPLSkin treatment system.the Information includes not only the accident protection regulations the products comply with,but also the effective regarding proper use of the products.

Cold head
When using, select the Cold head and enter the function panel. MODE: By default, only mode A is available.
TIME: The default is 30 minutes, adjustable from Oto 60 minutes. When it is 0, the instrument will stop working.
ENERGY: Adjust the working energy of the working head. The greater the number, the greater the energy. The 10 gears can be adjusted.
1,Help skin firmness, maintain elasticity, prevent allergies and other problems;
2,Shrink pores, lock water and reduce wrinkles;

BIO&LED
When using, select the BIO&LED head and enter the function panel.
MODE: There are four (A/B/C/D) micro-electric massage modes, which can be selected according to personal preferences.
TIME: The default is 30 minutes, adjustable from Oto 60 minutes. When it is 0, the instrument will stop working.
ENERGY: Adjust the micro-electric energy of the working head. The larger the number, the greater the energy. The 10th gear can be adjusted.
LEDCOLOUR:Adjust the light color. The light sequence is red light, green light, blue light, orange light, yellow light, purple light, blue light, circular lighta
LIGHT:Adjust the light brightness, The 10 gears can be adjusted.
Application : forehead. eyes' around, cheek, mouth, double chin, neck, body
Microcurrent-safe andpainless facial helps erase fine lines and wrinkles, while firming your skin and defining your features

EMS head
When using, select the EMS head and enter the function panel. MODE: There are four (A/B/C/D) micro-electric massage modes, which can be selected according to personal preferences.
TIME: The default is 30 minutes, adjustable from Oto 60 minutes. When it is 0, the instrument will stop working.
ENERGY: Adjust the micro-electric energy of the working head. The larger the number, the greater the energy. The 10th gear can be adjusted.
HOT:Adjust the working head temperature, adjustable at 10 gears.


It is a non-invasive slimming treatment technology that can burn fat while exercising Just like completing 20,000 sit-ups or squats in just 30 minutes, every 2 to 3 weeks, during 4 to 6 treatments, average fat decreases and muscle mass increases. The treatment area includes the abdomen, buttocks, arms and thighs.safe and comfortable treatment

Must know before use
1.Do not use on your original and dry skin surface, it will burn your skin. Make sure you apply cream or oils to your skin then you can use.
2.When using, there must be an aqueous medium (essential oil/creams, etc.),otherwise it will damage to the machine Do not use on the same part for too long, and avoid body parts with bones.
3.Do not connect the power until probe is well installed.
4.The machine is not allowed to replace probe when in the charging state.
5.Please take off the metal jewelry when using the machine.
6.When the machine is used for 1 hour, please stop for 10 minutes to let the machine rest.
7.Make sure you turn off the power after using, and clean the probe keep good maintenance for next time use.
8.Please keep the probe clean every time, use a dry cloth to wipe it, do not use water to clean.
9.After using, clean you skin and apply hydrating mask or creams, oils after 10 minutes.
10.When using 80KHead, some people may experience tinnitus. This is normal because this sound wave exceeds the range of human sound waves.

Reviews (0)
0    Write a review
Note: HTML is not translated!

There are no reviews for this product.

FAQs
Ask Question

There are no faqs for this product.

Frequently Bought Together

0 items selected

$0